RUSSIAN JOURNAL OF EARTH SCIENCES, VOL. 18, ES4003, doi:10.2205/2018ES000626, 2018


Figure 7. Examples of jump detection using JM algorithm. The original magnetogram is given on the upper plot; recognized jumps are marked with red. The lower plot provides the heater status information within the same period. Vertical rectangles outline the heater transition state between "on" and "off". Grey rectangles correspond to correlation between jumps and heater switches. Yellow rectangles correspond to correlation absence, i.e. no jumps associated with heater switches.


      Powered by MathJax


Citation: Soloviev A., Sh. Bogoutdinov, S. Agayan, R. Redmon, T. M. Loto'aniu, H. J. Singer (2018), Automated recognition of jumps in GOES satellite magnetic data, Russ. J. Earth Sci., 18, ES4003, doi:10.2205/2018ES000626.


Generated from LaTeX source by ELXpaper, v.1.5 software package.